SDC Firmware Download

SDC Firmware v1.24.0

Feature Updates
  • French update.
  • Added P116 for P82's "2" function. It is the count completion signal output time setting.
  • Changed maximum RPM of SD1500.
Bug Fixes
  • Improved bit socket tray #8 error.
  • Improved driver lock function error when setting P86(Start angle control) #0 (Disable)

PC Software

Version1.24.0
Size354.48 KB
Downloaded17 times
Create Updated2017-01-26
Please login

SDC Firmware v1.23.0

Feature Updates
  • Added P20(External IO Function Select)'s function. #5, for PLC except Run by manual screwdriver.

PC Software

Version1.23.0
Size344.41 KB
Downloaded6 times
Create Updated2017-01-12
Please login

SDC Firmware v1.22.0

Bug Fixes
  • When selecting Converted-Torque-Limit, Error 335 from minus direction has not been found and it has modified. In Converted-Torque, the value below tolerance range of minus limit is modified to be detected.

PC Software

Version1.22.0
Size343.46 KB
Downloaded4 times
Create Updated2017-01-12
Please login

SDC Firmware v1.21.0

Feature Updates
  • Changed Converted-torque-limit(P59). 0~10% → 0~25%

PC Software

Version1.21.0
Size343.53 KB
Downloaded190 times
Create Updated2016-11-03
Download

SDC Firmware v1.20.0

Feature Updates
  • Deleted the function P64,65,66,69 due to Doga's request
  • Added Franch service in Smart Manager
  • Modified the manual of Smart manager briefly
  • Changed the alternative setting range from 1-8 to 1-9(9 means multi sequence A) in auto sequence when using by setting model(P138,139 :enable)
Bug Fixes
  • Solved the problem that was unable graph monitoring in Smart manager because of a differnce of indicating a decimal point between Europe and Asia
PC Software

Version1.20.0
Size343.41 KB
Downloaded16 times
Create Updated2016-05-18
Please login

SDC Firmware v1.18.7

Feature Updates
  • If the selected model is changed, the preset value of the preset item in the real time monitoring will be changed to model value. (For Data Manager - Denso only)
PC Software

Version1.18.7
Size365.04 KB
Downloaded13 times
Create Updated2016-03-09
Please login

SDC Firmware v1.18.6

Feature Updates
  • paramter 115 added : front panel lock or unlock
PC Software

History file

Version1.18.6
Size336.47 KB
Downloaded7 times
Create Updated2016-02-02
Please login

SDC Firmware v1.18.5

Feature Updates
  • Updated in order to use the data manager.
PC Software

Version1.18.5
Size336.40 KB
Downloaded7 times
Create Updated2015-12-21
Please login

SDC Firmware v1.18.4

Feature Updates
  • P50 modified from initial loosening speed to loosening speed up to maximum speed.
  • P68 parameter range is changed from 100-300 to 100-200
  • P70 parameter range is changed from 10-200 to 10-100
PC Software

Version1.18.4
Size105.11 KB
Downloaded8 times
Create Updated2015-10-26
Please login

SDC Firmware v1.18.0

Feature Updates
  • Model add : SD-060 (changed to the angle type because the speed of the reducer is increased from 2:1 to 2.127:1)
  • Parameter add : P90 (available to change the fastening completion signal through setting to 200 ~ 500ms.)
PC Software

 

Version1.18.0
Size330.70 KB
Downloaded10 times
Create Updated2015-09-14
Please login